TRANSIT-400MP - System Specifications

Features of the TRANSIT-400MP Charger include:

  • eTec's patented eTec Minit-Charger™ algorithm
  • Charge times (Typical High Voltage 250V-350V Applications)
    • 15 minutes or less (60-80% SOC)
    • 30 minutes or less (30-80% SOC)
  • Utilizes the eTec battery module to automatically identify voltage and battery chemistry
    • 36 V to 350V nominal battery pack voltage
    • Sealed (VRLA), flooded lead-acid and NiCad batteries
  • Rapid shutdown feature for safe operation
  • Battery connector options

Charger Specifications:

OUTPUT
Maximum Output Power: 33kW (Optional 150kW available)
Maximum Output Current: 400 Amps
Voltage Operating Range: 24VDC-500VDC
INPUT
Input Voltage: 480 VAC, 3-PH
Maximum Input Current: 80 Amps AC RMS
Frequency: 60 Hz
Total Harmonic Distortion: < 5% (IEEE 519)
Power Factor: > .98
GENERAL
Dimensions (H/W/D): 9'/18'/8'
Weight: 12,000 lbs.
Operating Temperature: -25 Deg C to +40 Deg C
Enclosure: Outdoor Rated
Mounting: Ground
Battery Types: Sealed Valve Regulated Lead-Acid, Flooded Lead-Acid & Nickel Cadmium