Features of the GSE-400SP Charger include:

  • ECOtality North America's patented Minit-Charger™ algorithm
  • Charge times (Typical Low Voltage 80V GSE Applications)
    • 30 minutes or less (60-80% SOC)
    • 45 minutes or less (30-80% SOC)
  • Utilizes the ECOtality North America battery module to automatically identify voltage and battery chemistry
    • 36 V to 350V nominal battery pack voltage
    • Sealed (VRLA), flooded lead-acid and NiCad batteries
  • Rapid shutdown feature for safe operation
  • BIW 9-Pin 400Amp Connector Standard (Optional configurations available)

Charger Specifications:

Output
Maximum Output Power: 33kW
Maximum Output Current: 400 Amps
Voltage Operating Range: 24VDC-500VDC

Input
Input Voltage: 480 VAC, 3-PH
Maximum Input Current: 51 Amps AC RMS
Frequency: 60 Hz
Total Harmonic Distortion: 5% (IEEE 519)
Power Factor: .98

General
Dimensions (H/W/D): 67"/40"/30"
Weight: 1500 lbs.
Operating Temperature: -25 Deg C to +40 Deg C
Enclosure: Outdoor Rated
Mounting: Ground
Battery Types: Sealed Valve Regulated Lead-Acid, Flooded Lead-Acid & Nickel Cadmium