GSE-400SP - System Specifications
Features of the GSE-400SP Charger include:
- eTec's patented eTec Minit-Charger algorithm
- Charge times (Typical Low Voltage 80V GSE Applications)
- 30 minutes or less (60-80% SOC)
- 45 minutes or less (30-80% SOC)
- Utilizes the eTec battery module to automatically identify voltage and battery chemistry
- 36 V to 350V nominal battery pack voltage
- Sealed (VRLA), flooded lead-acid and NiCad batteries
- Rapid shutdown feature for safe operation
- BIW 9-Pin 400Amp Connector Standard (Optional configurations available)
Charger Specifications:
Output
| Maximum Output Power: |
33kW |
| Maximum Output Current: |
400 Amps |
| Voltage Operating Range: |
24VDC-500VDC |
Input
| Input Voltage: |
480 VAC, 3-PH |
| Maximum Input Current: |
51 Amps AC RMS |
| Frequency: |
60 Hz |
| Total Harmonic Distortion: |
5% (IEEE 519) |
| Power Factor: |
.98 |
General
| Dimensions (H/W/D): |
67"/40"/30" |
| Weight: |
1500 lbs. |
| Operating Temperature: |
-25 Deg C to +40 Deg C |
| Enclosure: |
Outdoor Rated |
| Mounting: |
Ground |
| Battery Types: |
Sealed Valve Regulated Lead-Acid, Flooded Lead-Acid & Nickel Cadmium |
|