GSE-200DP - System Specifications

Features of the GSE-200DP Charger include:

  • eTec's patented eTec Minit-Charger™ algorithm
  • 15 kW DC output
  • Each port is rated at 200 Amps; Maximum output limited to 15kW
  • UL/CSA rated for safety assurance
  • CANOpen vehicle protocol provides standard vehicle communications
  • Charge times (Typical GSE Battery)
    • 1 hour or less (Starting at 60% SOC to 80% SOC)
    • 2 hours or less (Starting at 30% SOC to 80% SOC)
  • eTec CANOpen battery module to identify voltage and battery chemistry
  • 24 V to 96V automatic operation
  • Capable of charging both sealed (VRLA) and flooded batteries without adjustment
  • Automatic Equalization for long battery life
  • Rapid Shutdown Feature for Safe Operation
  • Temperature Compensated
  • Optional Connector/Cord sets to conform to any airline requirement
  • Pedestal Feet Shown Optional
  • Power Quality Meets IEC 61000-3-4

Charger Specifications:

Output
Maximum Output Power: 15kW
Maximum Output Current: 200 Amps
Minimum Output Current: 8 Amps
Voltage Operating Range: 18VDC-120VDC

Input
Input Voltage: 480 VAC, 3-PH
Maximum Input Current: 24 Amps AC RMS
Frequency: 50/60 Hz
Power Quality: Meets IEEE-519 and IEC 6100-3-4

General
Dimensions (H/W/D): 64"/30"/27" (including 16" stand)
Weight: 950 lbs.
Operating Temperature: -25 °C to +40 °C
Enclosure: Outdoor Rated
Mounting: Ground or Wall
Battery Types: Sealed Valve Regulated Lead-Acid or Flooded Lead-Acid

Performance Specifications:

The GSE-200DP...
  • is deliverable as a complete unit and requires no more than incidental assembly at the installation location.
  • is fully self-contained requiring no power other than that provided at 480 VAC.
  • utilizes an outdoor rated cabinet.
  • remains fully functional in temperatures ranging from -25°C to 40°C.
  • has an automatic equalization cycle provides an equalizing charge to the GSE vehicle upon completion of that vehicle’s rapid charge cycle
  • is capable of charging flooded lead acid, absorbed glass mat lead acid and gel electrolyte lead acid battery types.
  • will charge batteries with capacities from 20Ahr to 1000Ahr.
  • is capable of recognizing and rapid charging various combinations of battery type, capacity and voltage without operator intervention of any type.
  • has each port rated at 200 amperes with a 15-kilowatt overall power limit.
  • includes a vehicle-based Management Information System which collects and stores charge data onboard each vehicle.
  • has an optional Internet based Management Information System or external Point of Sale (POS Fuel Card) system can be provided for billing purposes, or providing other end-use customer data.